alarms.cfg
The alarms.cfg file is a series of one or more Pikt alarm scripts. Use Pikt scripts for system monitoring, to report and fix problems, to enhance system security, and to handle all sorts of routine system administration tasks.
For example, here is a Pikt script to report system downages, as it might appear in alarms.cfg (or one of its #include files):
/////////////////////////////////////////////////////////////////////////////// // // PIKT alarms.cfg -- Pikt scripts and alarm definitions // /////////////////////////////////////////////////////////////////////////////// ... SystemsDown init status =piktstatus level =piktlevel task "Report systems down or off the network" input proc "=piktc -L -H down sick" dat $host 1 keys $host #ifdef debug rule output $host #endifdef rule // initially, assume system is up set $state = "+" rule // do the initial poll quickly if =pingfail($host, 1, 1) // if the first ping failed, try again with more retries // and longer timeouts if =pingfail($host, 3, 5) set $state = "-" // always report new downages if $state ne %state output mail "$host is down, or off the network (ping failure)" #if mission_critical // only for mission-critical systems // report continuing downages, but just hourly else =hourly(output mail "$host is down, or off the network (ping failure)", ) #endif fi next fi fi #ifdef verbose rule // report when systems come back up after a downage // if state was "-", is now "+", report change if #defined(%state) && $state ne %state output mail "$host is back up" fi #endifdef ...For a more detailed discussion of Pikt scripts, see the Pikt Script Language. Refer to the sample alarms.cfg for many more examples.
prev page | 1st page | next page |